Heating & Furnace Services Morton Grove, IL
We specialize in heating and cooling homes across Chicagoland, so no matter what heating and furnace issues you face, from preventative maintenance challenges to fixes and installations, we can help you stay warm all winter. Here are just a few of the services you can expect us to help you with:
- Furnace repair and replacement
- Indoor air quality (filtration)
- Humidifiers
- Zoning
- Gas leak repair
- Radiant floor heating
- Snow melt systems
- Boiler repair and replacement
When snow, ice and frost hit Morton Grove, know that Home Comfort is ready for your call should your heating system need our services, night or day.
Air Conditioning & Cooling Services
You can also depend on Home Comfort throughout the hot summer months when Morton Grove residents rely on their air conditioning systems to keep them cool. If your air conditioning system is in need of maintenance or repair work, we can help with the following and more:
- Air conditioner repair and replacement
- Ductless A/C systems
- SpacePak/Unico
- Dehumidification
- Programmable thermostats
- Zoning
- Attic fans
With vast knowledge of a broad range of heating and cooling systems, we’re confident we can help you with any issues you encounter.
Your Trusted Morton Grove HVAC Company
As a local, family owned business, we prioritize your needs, and with 24-hour emergency service available, you know we’ll always put you first. When you’re in need of emergency heating or cooling services, it’s essential to have a team you can trust ready to serve you.
Residents of Morton Grove may also contact the Morton Grove Public Works Department for information on public concerns, located at:
Contact us today to find out more about all our services in Morton Grove and the surrounding areas of Skokie, Niles, Glenview and beyond.
Recent Jobs and Reviews in Morton Grove, IL
Job Locations and Reviews
Responded to no cooling complaint at commercial office space. Upon inspection, discovered failed contactor with severely burnt and corroded contact points showing evidence of electrical arcing and thermal damage. Removed defective contactor and replaced with new unit. Verified proper electrical connections, tested system operation, and confirmed cooling restored to affected space.
Completed spring preventive maintenance on commercial air conditioning unit per customer care plan. Performed thorough cleaning and inspection of system components, verified thermostat operation showing 75°F setpoint with proper cooling mode functionality. Observed significant frost accumulation on evaporator coil and refrigerant lines during inspection, indicating potential airflow restriction or refrigerant charge issue requiring further diagnostic evaluation.
Completed comprehensive full system HVAC estimate for commercial facility. Performed detailed measurements and documentation of existing air handling equipment, ductwork configurations, and mechanical room layout to provide accurate replacement specifications. Assessed current system components including vertical air handler units, sheet metal ductwork, and associated electrical infrastructure to determine complete system replacement requirements.
Completed commercial HVAC maintenance agreement service on two rooftop air conditioning units located in warehouse facility. Performed comprehensive preventive maintenance per contract protocol including filter replacement with one 20x20x1 and one 16x20x1 filter, system inspection, and equipment data collection. Documented deteriorated capacitor showing significant corrosion and terminal degradation requiring future replacement recommendation.
Completed spring preventive maintenance on residential split system air conditioning unit per comfort plan agreement. Performed comprehensive clean and check procedures on Carrier HVAC system, including outdoor condenser unit and indoor air handler/furnace assembly. Inspected electrical connections, disconnect box, and conduit at exterior unit; verified proper airflow through condenser coil fins; checked refrigerant lines and condensate drainage. Evaluated indoor equipment installation, ductwork connections, and system accessibility in basement location. All components operating within normal parameters; system ready for cooling season.
Performed comprehensive Comfort Plan clean and check maintenance on single-system HVAC unit. Conducted thorough inspection of furnace and air conditioning components, verifying proper operation of high-efficiency heating system with PVC venting configuration. Measured supply air temperatures at ductwork using calibrated digital thermometer to confirm system performance parameters. Inspected all accessible mechanical components including furnace cabinet, ductwork connections, and ventilation piping. Verified equipment labels and manufacturer specifications were properly displayed. System found to be operating within normal parameters with no deficiencies noted requiring immediate attention.
Completed scheduled preventive maintenance on two commercial rooftop HVAC units per maintenance agreement. Performed comprehensive inspection of both RTU systems including electrical components, control wiring, and interior compartments. All systems operational with no deficiencies noted at time of service.
Completed spring clean and check maintenance on single HVAC system per comfort plan agreement. Performed comprehensive inspection of outdoor condensing unit located on side of home, including cleaning of condenser coil, inspection of electrical connections and control board assembly, and verification of proper refrigerant temperatures. Accessed and photographed multi-layer control board system showing proper wiring connections, heat sink assembly, and integrated circuit components in good operating condition. Measured and documented supply air temperature at evaporator coil reading 43.3°F, confirming adequate cooling capacity and proper system operation. All components functioning within normal parameters with no deficiencies noted at time of service.
Responded to service call for air conditioning unit running continuously. Performed comprehensive Comfort Plan Clean and Check maintenance on single system including inspection of outdoor condensing unit, verification of electrical components using clamp meter, and assessment of refrigerant lines and connections. Provided customer with 15x20x1 air filter for future use.
Responded to no cooling complaint on commercial rooftop unit. Previous breaker issue had been addressed, but unit still not cooling properly. Upon arrival, accessed rooftop unit and removed side panel to inspect internal components. Connected manifold gauges to measure refrigerant pressures and temperatures. Initial diagnostic readings showed suction pressure at 58.2 psig with 63.6°F temperature, resulting in 31.2°F superheat on R-22 system. Liquid line pressure measured 183.7 psig at 80.7°F with 15.0°F subcooling. System analysis indicated abnormal operating conditions preventing adequate cooling performance. Documented beginning temperatures and pressures for diagnostic purposes.
Returned to commercial rooftop unit to complete previously diagnosed repair. Replaced failed 45/5 dual run capacitor on HVAC system. Removed weathered capacitor showing signs of corrosion and installed new replacement unit. Secured capacitor with mounting bracket and reconnected all electrical terminals. Verified system operation and confirmed thermostat responding properly with unit cycling correctly. Collected final payment for completed repair work.
Replaced failed electrical disconnect switch for rooftop air conditioning unit ending in 9003. Installed new disconnect box with proper conduit connections and verified electrical connections at circuit breaker panel. System tested and confirmed operational upon completion, with invoice emailed to payables department as requested.
Completed preventive maintenance clean and check on two air conditioning systems per comfort plan agreement. Both units were found to be one pound low on refrigerant and were recharged to manufacturer specifications. Documented low refrigerant charge for monitoring during next spring's maintenance visit, with recommendation to schedule service in June or when ambient temperatures exceed 65 degrees to allow proper system assessment. Advised that if refrigerant loss reoccurs, further leak detection and system evaluation will be necessary to determine viability of repair versus replacement. Customer reported noise concerns with recently installed furnace but later determined likely cause to be birds in vicinity rather than mechanical issue. Customer requested thermostat switch replacement; advised that scope of work is limited to simple switch replacement and any additional electrical modifications would require licensed electrician. Photographed both thermostat units showing operational
Responded to no cooling complaint at commercial office space. Upon arrival, performed diagnostic testing on outdoor condensing unit. Inspected electrical components including contactor and run capacitor using clamp meter to verify proper operation. Capacitor tested within acceptable microfarad range. Contactor showed heavy dirt and grime accumulation but functionally operational. System powered up and cycled normally with all electrical connections secure. Unit returned to normal cooling operation.
Responded to report of non-operational air conditioning system at commercial property with new tenants. Upon arrival, accessed rooftop unit RTU ID 102-807 and performed comprehensive system inspection. Verified electrical components including capacitor, contactor, and associated wiring connections. Conducted operational testing to assess system functionality following building vacancy period. Unit evaluated and confirmed ready for cooling season operation.
Responded to service call for non-operational rooftop AC unit at commercial facility that had been vacant during fall heating season. Upon arrival, performed comprehensive inspection of dual packaged rooftop units including visual assessment of external components, electrical connections, and mechanical systems. Accessed internal compartments to examine wiring, control boards, and safety devices. Verified unit operation and functionality to ensure proper cooling capacity for newly occupied space.
Responded to reported roof leak at commercial facility. Upon investigation following roofer's assessment indicating water entry from mechanical unit, inspected rooftop HVAC equipment and associated ductwork. Examined RTU installations on gravel ballast roof system and interior ductwork connections for signs of water intrusion or condensate drainage issues that could be causing leak into tenant space.
Completed spring maintenance clean and check on outdoor condensing unit per service comfort plan. Upon arrival, discovered AC system had been previously replaced by another company and updated equipment records accordingly. Performed visual inspection and noted one of four access panels could not be removed for full service access. Inspected accessible electrical connections, control wiring, and junction assembly - all connections found secure with proper wire management. Observed significant dust accumulation within unit due to limited panel access. Cleaned accessible components and verified unit operation. Recommend scheduling follow-up service to address inaccessible panel and complete thorough coil cleaning to restore optimal airflow and system efficiency.
Responded to no cooling complaint on commercial rooftop unit. Performed system inspection and found dirty evaporator coil restricting airflow and reducing cooling capacity. Cleaned coil assembly, verified proper operation of blower and controls, and restored unit to normal cooling function.
Completed spring preventative maintenance on two air conditioning systems per comfort plan agreement. Performed comprehensive clean and check procedures including refrigerant line temperature measurements using calibrated digital instruments, verified proper insulation on suction lines, and conducted full system operational testing. All equipment found operating within manufacturer specifications with no deficiencies noted.