24/7 Heating, & AC Services in Chicago, IL | Local HVAC
24/7 Emergency Service
Contact the professionals at Home Comfort to take care of your HVAC emergency, no matter the time of day or day of the week. Did you know that any one of our super friendly technicians is on call 24/7? You're not the first customer to experience the unfortunate circumstance of no heat or no A/C at an inopportune time. We’re here for you. Call 847-824-4336 to get emergency HVAC services in Northwest Chicagoland & the surrounding areas.

Heating & Cooling Services in Chicago, IL

Maintaining consistent comfort in your Chicago-area home means having a reliable HVAC technician you can trust to service all your heating and cooling equipment. Home Comfort Services has proudly delivered the comprehensive HVAC solutions that Chicago residents have trusted since 1998.

With seven-day-a-week HVAC repair availability and a team of background-checked technicians, we go above and beyond to make your home more comfortable through our powerful service solutions.

Schedule heating or air conditioning services in Chicago today by calling our team at 847-824-4336!

Home Comfort technician at the door of a Chicago homeowner

Dependable Cooling Services

While summers in Chicago are mild, with average highs of 80 degrees F, high humidity levels over 75% can make the summer season downright intolerable without a properly functioning air conditioner. Whether you have a heat pump, ductless mini-split, or central AC unit, our cooling experts are prepared to handle all of your service requests, including:

Service and Maintenance 7 Days a Week (224) 757-1647

Top-Rated Heating Services

With winter lows averaging 25 degrees F and an annual snowfall of 37 inches, Chicago homeowners need a source of reliable heat to survive the coldest days of the year. Our team can service any make or model heating equipment, including gas and electric furnaces and boiler systems. We are here to assist whenever you need:

Keep your home warm and cozy all winter by calling Home Comfort Services at 847-824-4336 to book your heating service appointment in Chicago today!

Superior Air Quality Services

Did you know that the Environmental Protection Agency ranked poor indoor air quality as one of the top concerns for homeowners? It’s true — the air inside your home can be up to 5 times more polluted than the air outside, leading to serious health issues for your household and reduced efficiency for your HVAC equipment.

At Home Comfort Services, our team offers various indoor air quality solutions to eliminate harmful contaminants from your air supply. We specialize in:

  • Ductwork repairs & replacements
  • Air purifier installation
  • Air scrubber installation
  • Humidifier services
  • Dehumidifier services

Breathe easy in your Chicago-area home by calling 847-824-4336 to book indoor air quality services with our team today!

Why Choose Home Comfort in Chicago?

As Northwest Chicagoland’s heating and air conditioning experts since 1998, Home Comfort Services is proud to deliver a comprehensive range of HVAC solutions that local families can trust to keep their homes safe and comfortable all year. With seven-day-a-week repair availability, we are here to act when you need us most, restoring reliable comfort to your home in no time.

We are committed to integrity and professionalism in everything we do, providing honesty and expertise to our customers with every service we provide. As Premium Customer Conveniences, we remain passionate about bringing the highest quality products and solutions to your home.

Get the high-quality HVAC service experience you deserve by calling 847-824-4336 to book your heating and cooling services with Home Comfort today!

Recent Jobs and Reviews in Chicago, IL

Chicago, IL at a glance

Home Comfort Services, Inc. has completed 20 jobs in Chicago, IL in July 2026.

The most recent job was on July 21, 2026.

Job Locations and Reviews

Responded to no cooling call for new customer. Performed diagnostic testing on outdoor condensing unit and identified failed dual-run capacitor (TRCFD5075, 50+7.5 MFD). Verified capacitor failure using digital multimeter, which showed significantly degraded capacitance reading of 7.48 microfarads. Replaced defective TITAN PRO motor run capacitor with new unit rated at 440/370VAC. Tested system operation, confirmed proper compressor and condenser fan motor function. Recorded all equipment information and discussed preventative maintenance options with customer. System restored to normal cooling operation.
Responded to no cooling call for new customer. Performed diagnostic testing on outdoor condensing unit and identified failed dual-run capacitor (TRCFD5075, 50+7.5 MFD). Verified capacitor failure using digital multimeter, which showed significantly degraded capacitance reading of 7.48 microfarads. Replaced defective TITAN PRO motor run capacitor with new unit rated at 440/370VAC. Tested system operation, confirmed proper compressor and condenser fan motor function. Recorded all equipment information and discussed preventative maintenance options with customer. System restored to normal cooling operation.
Jose E.
Jose E. Checked in
Responded to no cooling call for new customer. Performed diagnostic testing on outdoor condensing unit and identified failed dual-run capacitor (TRCFD5075, 50+7.5 MFD). Verified capacitor failure using digital multimeter, which showed significantly degraded capacitance reading of 7.48 microfarads. Replaced defective TITAN PRO motor run capacitor with new unit rated at 440/370VAC. Tested system operation, confirmed proper compressor and condenser fan motor function. Recorded all equipment information and discussed preventative maintenance options with customer. System restored to normal cooling operation.
Chicago, IL 60645
Completed comprehensive Comfort Plan maintenance service on two air conditioning systems. Performed full clean and check procedures on both indoor and outdoor units, including inspection of evaporator coils, condensate drain lines, and PVC drainage system components. Examined and serviced outdoor condenser units, verifying proper operation of fan assemblies, condenser coils, and refrigerant line connections. Inspected electrical connections, control panels, and system wiring for both units. All components found operating within normal parameters, with no deficiencies noted requiring immediate attention. Systems tested and confirmed functioning properly upon completion of scheduled maintenance.
Completed comprehensive Comfort Plan maintenance service on two air conditioning systems. Performed full clean and check procedures on both indoor and outdoor units, including inspection of evaporator coils, condensate drain lines, and PVC drainage system components. Examined and serviced outdoor condenser units, verifying proper operation of fan assemblies, condenser coils, and refrigerant line connections. Inspected electrical connections, control panels, and system wiring for both units. All components found operating within normal parameters, with no deficiencies noted requiring immediate attention. Systems tested and confirmed functioning properly upon completion of scheduled maintenance.
Furqan J.
Furqan J. Checked in
Completed comprehensive Comfort Plan maintenance service on two air conditioning systems. Performed full clean and check procedures on both indoor and outdoor units, including inspection of evaporator coils, condensate drain lines, and PVC drainage system components. Examined and serviced outdoor condenser units, verifying proper operation of fan assemblies, condenser coils, and refrigerant line connections. Inspected electrical connections, control panels, and system wiring for both units. All components found operating within normal parameters, with no deficiencies noted requiring immediate attention. Systems tested and confirmed functioning properly upon completion of scheduled maintenance.
Chicago, IL 60631
Responded to no cooling call for first floor system under warranty. Upon arrival, accessed rooftop Lennox unit and performed diagnostic evaluation. Verified unit levelness and conducted thorough inspection of equipment. System assessed and found to be operating within normal parameters following inspection. No defects identified during warranty service call.
Responded to no cooling call for first floor system under warranty. Upon arrival, accessed rooftop Lennox unit and performed diagnostic evaluation. Verified unit levelness and conducted thorough inspection of equipment. System assessed and found to be operating within normal parameters following inspection. No defects identified during warranty service call.
Travis S.
Travis S. Checked in
Responded to no cooling call for first floor system under warranty. Upon arrival, accessed rooftop Lennox unit and performed diagnostic evaluation. Verified unit levelness and conducted thorough inspection of equipment. System assessed and found to be operating within normal parameters following inspection. No defects identified during warranty service call.
Chicago, IL 60614
Responded to service call for reported water leak in HVAC duct system causing ceiling mold growth. Performed diagnostic inspection of residential utility closet housing furnace, water heater, and associated ductwork. Identified water damage and staining on ceiling near HVAC equipment, with visible discoloration indicating active moisture intrusion. Inspected galvanized steel plenum, ductwork transitions, and condensate drainage system for leak sources. Documented equipment conditions and leak evidence with photographs. Provided customer with flat-rate repair options to address leak source and prevent further water damage, allowing mold remediation to proceed safely.
Responded to service call for reported water leak in HVAC duct system causing ceiling mold growth. Performed diagnostic inspection of residential utility closet housing furnace, water heater, and associated ductwork. Identified water damage and staining on ceiling near HVAC equipment, with visible discoloration indicating active moisture intrusion. Inspected galvanized steel plenum, ductwork transitions, and condensate drainage system for leak sources. Documented equipment conditions and leak evidence with photographs. Provided customer with flat-rate repair options to address leak source and prevent further water damage, allowing mold remediation to proceed safely.
Jose E.
Jose E. Checked in
Responded to service call for reported water leak in HVAC duct system causing ceiling mold growth. Performed diagnostic inspection of residential utility closet housing furnace, water heater, and associated ductwork. Identified water damage and staining on ceiling near HVAC equipment, with visible discoloration indicating active moisture intrusion. Inspected galvanized steel plenum, ductwork transitions, and condensate drainage system for leak sources. Documented equipment conditions and leak evidence with photographs. Provided customer with flat-rate repair options to address leak source and prevent further water damage, allowing mold remediation to proceed safely.
Chicago, IL 60657
Responded to no cooling call where unit was running but delivering warm air. Upon inspection, discovered supply air temperature at 170°F, indicating heating mode operation instead of cooling. Verified thermostat settings, corrected reversing valve or control issue causing system to operate in heat mode during cooling demand, and restored proper cooling operation to outdoor condensing unit.
Responded to no cooling call where unit was running but delivering warm air. Upon inspection, discovered supply air temperature at 170°F, indicating heating mode operation instead of cooling. Verified thermostat settings, corrected reversing valve or control issue causing system to operate in heat mode during cooling demand, and restored proper cooling operation to outdoor condensing unit.
Michael O.
Michael O. Checked in
Responded to no cooling call where unit was running but delivering warm air. Upon inspection, discovered supply air temperature at 170°F, indicating heating mode operation instead of cooling. Verified thermostat settings, corrected reversing valve or control issue causing system to operate in heat mode during cooling demand, and restored proper cooling operation to outdoor condensing unit.
Chicago, IL 60630
Responded to no cooling call on residential air conditioning system. Upon arrival, performed system diagnostics and inspected outdoor unit components. Found capacitor showing signs of wear and dust accumulation, with visible electrical connections requiring attention. Inspected refrigerant lines and electrical wiring connections at outdoor unit, noting moisture presence on suction line indicating system had been attempting to operate. Evaluated capacitor specifications and electrical connections to compressor circuit. Documented component conditions through photography for service records. System required capacitor replacement and electrical connection service to restore cooling operation.
Responded to no cooling call on residential air conditioning system. Upon arrival, performed system diagnostics and inspected outdoor unit components. Found capacitor showing signs of wear and dust accumulation, with visible electrical connections requiring attention. Inspected refrigerant lines and electrical wiring connections at outdoor unit, noting moisture presence on suction line indicating system had been attempting to operate. Evaluated capacitor specifications and electrical connections to compressor circuit. Documented component conditions through photography for service records. System required capacitor replacement and electrical connection service to restore cooling operation.
David R.
David R. Checked in
Responded to no cooling call on residential air conditioning system. Upon arrival, performed system diagnostics and inspected outdoor unit components. Found capacitor showing signs of wear and dust accumulation, with visible electrical connections requiring attention. Inspected refrigerant lines and electrical wiring connections at outdoor unit, noting moisture presence on suction line indicating system had been attempting to operate. Evaluated capacitor specifications and electrical connections to compressor circuit. Documented component conditions through photography for service records. System required capacitor replacement and electrical connection service to restore cooling operation.
Chicago, IL 60614
Replaced failed 1/2 HP 1075 RPM 230V totally enclosed condenser fan motor on rooftop air conditioning unit. Installation included new motor, fan blade, and dual capacitor with one-year warranty on parts and labor. System will require refrigerant pressure testing following motor replacement to determine if additional refrigerant charge or further repairs are necessary due to the unit's age, condition, and obsolete refrigerant type.
Replaced failed 1/2 HP 1075 RPM 230V totally enclosed condenser fan motor on rooftop air conditioning unit. Installation included new motor, fan blade, and dual capacitor with one-year warranty on parts and labor. System will require refrigerant pressure testing following motor replacement to determine if additional refrigerant charge or further repairs are necessary due to the unit's age, condition, and obsolete refrigerant type.
David R.
David R. Checked in
Replaced failed 1/2 HP 1075 RPM 230V totally enclosed condenser fan motor on rooftop air conditioning unit. Installation included new motor, fan blade, and dual capacitor with one-year warranty on parts and labor. System will require refrigerant pressure testing following motor replacement to determine if additional refrigerant charge or further repairs are necessary due to the unit's age, condition, and obsolete refrigerant type.
Chicago, IL 60642
Replaced failed thermal expansion valve (TXV) located in attic on residential split system air conditioning unit. Part was ordered and picked up from supply house prior to installation. System tested and verified proper cooling operation with thermostat cycling correctly between cooling modes.
Replaced failed thermal expansion valve (TXV) located in attic on residential split system air conditioning unit. Part was ordered and picked up from supply house prior to installation. System tested and verified proper cooling operation with thermostat cycling correctly between cooling modes.
Jose E.
Jose E. Checked in
Replaced failed thermal expansion valve (TXV) located in attic on residential split system air conditioning unit. Part was ordered and picked up from supply house prior to installation. System tested and verified proper cooling operation with thermostat cycling correctly between cooling modes.
Chicago, IL 60625
Removed existing humidifier from HVAC system, patched the opening in ductwork, and capped and insulated the water supply line to prevent future issues. Rebuilt and properly secured the PVC condensate drain line where it connects to the main plumbing stack to ensure proper drainage and prevent leaks. Installed WiFi-enabled wet switch for remote monitoring and leak detection, and provided instruction on mobile app operation for system alerts and notifications.
Removed existing humidifier from HVAC system, patched the opening in ductwork, and capped and insulated the water supply line to prevent future issues. Rebuilt and properly secured the PVC condensate drain line where it connects to the main plumbing stack to ensure proper drainage and prevent leaks. Installed WiFi-enabled wet switch for remote monitoring and leak detection, and provided instruction on mobile app operation for system alerts and notifications.
Craig S.
Craig S. Checked in
Removed existing humidifier from HVAC system, patched the opening in ductwork, and capped and insulated the water supply line to prevent future issues. Rebuilt and properly secured the PVC condensate drain line where it connects to the main plumbing stack to ensure proper drainage and prevent leaks. Installed WiFi-enabled wet switch for remote monitoring and leak detection, and provided instruction on mobile app operation for system alerts and notifications.
Chicago, IL 60641
Responded to no cooling call at residential property. Upon arrival, performed diagnostic inspection of air conditioning system. Inspected condensing unit components including capacitor and electrical connections. Found capacitor with proper MARS2 replacement specifications installed and wiring connections secure. Verified refrigerant line sets and service tags properly labeled. Documented equipment condition with photos showing capacitor assembly, electrical terminations, and refrigerant piping infrastructure. System operational at time of inspection.
Responded to no cooling call at residential property. Upon arrival, performed diagnostic inspection of air conditioning system. Inspected condensing unit components including capacitor and electrical connections. Found capacitor with proper MARS2 replacement specifications installed and wiring connections secure. Verified refrigerant line sets and service tags properly labeled. Documented equipment condition with photos showing capacitor assembly, electrical terminations, and refrigerant piping infrastructure. System operational at time of inspection.
Travis S.
Travis S. Checked in
Responded to no cooling call at residential property. Upon arrival, performed diagnostic inspection of air conditioning system. Inspected condensing unit components including capacitor and electrical connections. Found capacitor with proper MARS2 replacement specifications installed and wiring connections secure. Verified refrigerant line sets and service tags properly labeled. Documented equipment condition with photos showing capacitor assembly, electrical terminations, and refrigerant piping infrastructure. System operational at time of inspection.
Chicago, IL 60642
Performed comprehensive clean and check maintenance on two heat pump systems per comfort plan agreement. Conducted thorough inspection of both units including temperature differential testing, amperage readings, and operational verification. Supply air temperature measured at 59.7°F with system operating properly. Electrical measurements showed 420.0 volts and 38.18 amp draw, indicating normal operating parameters. Inspected all electrical connections, thermocouple wiring, and blower assembly components. Evaluated existing steam humidifier condition and provided customer with detailed repair versus replacement options based on current system performance and anticipated longevity. All safety controls tested and verified operational. Both heat pump systems left in proper working condition with no immediate concerns noted.
Performed comprehensive clean and check maintenance on two heat pump systems per comfort plan agreement. Conducted thorough inspection of both units including temperature differential testing, amperage readings, and operational verification. Supply air temperature measured at 59.7°F with system operating properly. Electrical measurements showed 420.0 volts and 38.18 amp draw, indicating normal operating parameters. Inspected all electrical connections, thermocouple wiring, and blower assembly components. Evaluated existing steam humidifier condition and provided customer with detailed repair versus replacement options based on current system performance and anticipated longevity. All safety controls tested and verified operational. Both heat pump systems left in proper working condition with no immediate concerns noted.
Travis S.
Travis S. Checked in
Performed comprehensive clean and check maintenance on two heat pump systems per comfort plan agreement. Conducted thorough inspection of both units including temperature differential testing, amperage readings, and operational verification. Supply air temperature measured at 59.7°F with system operating properly. Electrical measurements showed 420.0 volts and 38.18 amp draw, indicating normal operating parameters. Inspected all electrical connections, thermocouple wiring, and blower assembly components. Evaluated existing steam humidifier condition and provided customer with detailed repair versus replacement options based on current system performance and anticipated longevity. All safety controls tested and verified operational. Both heat pump systems left in proper working condition with no immediate concerns noted.
Chicago, IL 60610
Responded to no cooling complaint. Upon arrival, found thermostat displaying 74°F actual temperature while set to 93°F in cooling mode with system calling for cooling and fan operation. Inspected electrical panel and verified power supply to HVAC equipment. Documented thermostat settings and electrical distribution panel condition for service records.
Responded to no cooling complaint. Upon arrival, found thermostat displaying 74°F actual temperature while set to 93°F in cooling mode with system calling for cooling and fan operation. Inspected electrical panel and verified power supply to HVAC equipment. Documented thermostat settings and electrical distribution panel condition for service records.
Jose E.
Jose E. Checked in
Responded to no cooling complaint. Upon arrival, found thermostat displaying 74°F actual temperature while set to 93°F in cooling mode with system calling for cooling and fan operation. Inspected electrical panel and verified power supply to HVAC equipment. Documented thermostat settings and electrical distribution panel condition for service records.
Chicago, IL 60641
Completed spring preventative maintenance on residential air conditioning system per comfort plan agreement. Outdoor condenser unit exhibited heavy accumulation of dirt, dust, and debris on coil fins prior to service. Performed thorough cleaning of condenser coils, inspected refrigerant lines with existing orange cable tie securing, and verified proper unit operation. System tested and confirmed operational following maintenance procedures.
Completed spring preventative maintenance on residential air conditioning system per comfort plan agreement. Outdoor condenser unit exhibited heavy accumulation of dirt, dust, and debris on coil fins prior to service. Performed thorough cleaning of condenser coils, inspected refrigerant lines with existing orange cable tie securing, and verified proper unit operation. System tested and confirmed operational following maintenance procedures.
Travis S.
Travis S. Checked in
Completed spring preventative maintenance on residential air conditioning system per comfort plan agreement. Outdoor condenser unit exhibited heavy accumulation of dirt, dust, and debris on coil fins prior to service. Performed thorough cleaning of condenser coils, inspected refrigerant lines with existing orange cable tie securing, and verified proper unit operation. System tested and confirmed operational following maintenance procedures.
Chicago, IL 60646
Responded to service call for ductless mini-split system experiencing cooling failure while heating mode remained operational. Performed diagnostic assessment of wall-mounted indoor unit in residential space currently undergoing renovation. Evaluated system performance, refrigerant levels, and control functions to identify cause of cooling malfunction. Presented equipment replacement options and provided comprehensive estimate for new mini-split installation to address failed cooling capacity. Documented existing equipment information and photographed current installation conditions including recently installed indoor unit with protective covering still in place.
Responded to service call for ductless mini-split system experiencing cooling failure while heating mode remained operational. Performed diagnostic assessment of wall-mounted indoor unit in residential space currently undergoing renovation. Evaluated system performance, refrigerant levels, and control functions to identify cause of cooling malfunction. Presented equipment replacement options and provided comprehensive estimate for new mini-split installation to address failed cooling capacity. Documented existing equipment information and photographed current installation conditions including recently installed indoor unit with protective covering still in place.
Bill S.
Bill S. Checked in
Responded to service call for ductless mini-split system experiencing cooling failure while heating mode remained operational. Performed diagnostic assessment of wall-mounted indoor unit in residential space currently undergoing renovation. Evaluated system performance, refrigerant levels, and control functions to identify cause of cooling malfunction. Presented equipment replacement options and provided comprehensive estimate for new mini-split installation to address failed cooling capacity. Documented existing equipment information and photographed current installation conditions including recently installed indoor unit with protective covering still in place.
Chicago, IL 60646
Completed Comfort Plan Clean and Check maintenance service on a two-system HVAC setup consisting of a furnace and air conditioning unit. Performed comprehensive inspection of all equipment, verified proper electrical operation with amperage readings at 25.4A, and documented system conditions with photos. All components found operating within normal parameters.
Completed Comfort Plan Clean and Check maintenance service on a two-system HVAC setup consisting of a furnace and air conditioning unit. Performed comprehensive inspection of all equipment, verified proper electrical operation with amperage readings at 25.4A, and documented system conditions with photos. All components found operating within normal parameters.
Furqan J.
Furqan J. Checked in
Completed Comfort Plan Clean and Check maintenance service on a two-system HVAC setup consisting of a furnace and air conditioning unit. Performed comprehensive inspection of all equipment, verified proper electrical operation with amperage readings at 25.4A, and documented system conditions with photos. All components found operating within normal parameters.
Chicago, IL 60657
Completed warranty quality audit on newly installed furnace, AC, and Solaris system. Investigated master bedroom temperature differential of 7 degrees compared to rest of condo. Diagnosed airflow restriction issue caused by improperly balanced or obstructed ductwork serving master bedroom zone. Accessed attic space and inspected duct runs, identifying damper positioning concerns. Adjusted zone dampers and verified proper airflow distribution. Reviewed furnace control board operation and confirmed system cycling normally with proper fault code display. Documented findings with customer and discussed ductwork modifications needed for optimal temperature balance throughout living space.
Completed warranty quality audit on newly installed furnace, AC, and Solaris system. Investigated master bedroom temperature differential of 7 degrees compared to rest of condo. Diagnosed airflow restriction issue caused by improperly balanced or obstructed ductwork serving master bedroom zone. Accessed attic space and inspected duct runs, identifying damper positioning concerns. Adjusted zone dampers and verified proper airflow distribution. Reviewed furnace control board operation and confirmed system cycling normally with proper fault code display. Documented findings with customer and discussed ductwork modifications needed for optimal temperature balance throughout living space.
Craig S.
Craig S. Checked in
Completed warranty quality audit on newly installed furnace, AC, and Solaris system. Investigated master bedroom temperature differential of 7 degrees compared to rest of condo. Diagnosed airflow restriction issue caused by improperly balanced or obstructed ductwork serving master bedroom zone. Accessed attic space and inspected duct runs, identifying damper positioning concerns. Adjusted zone dampers and verified proper airflow distribution. Reviewed furnace control board operation and confirmed system cycling normally with proper fault code display. Documented findings with customer and discussed ductwork modifications needed for optimal temperature balance throughout living space.
Chicago, IL 60634
Completed comprehensive tune-up and preventive maintenance on two air conditioning systems for new customer. Performed standard inspection protocols including filter evaluation, refrigerant level verification, electrical connection testing, condensate drain assessment, and overall system performance analysis. Documentation captured via photographs for service records, with all systems found operating within normal parameters upon completion of maintenance procedures.
Completed comprehensive tune-up and preventive maintenance on two air conditioning systems for new customer. Performed standard inspection protocols including filter evaluation, refrigerant level verification, electrical connection testing, condensate drain assessment, and overall system performance analysis. Documentation captured via photographs for service records, with all systems found operating within normal parameters upon completion of maintenance procedures.
Furqan J.
Furqan J. Checked in
Completed comprehensive tune-up and preventive maintenance on two air conditioning systems for new customer. Performed standard inspection protocols including filter evaluation, refrigerant level verification, electrical connection testing, condensate drain assessment, and overall system performance analysis. Documentation captured via photographs for service records, with all systems found operating within normal parameters upon completion of maintenance procedures.
Chicago, IL 60625
Responded to callback for recurring cooling issue following previous service visit. Upon arrival, verified thermostat displaying 73°F with customer reporting inadequate cooling and indoor temperature of 76°F. Inspected HVAC control board and wiring connections within air handler, checking all low-voltage control wiring, power connections, and relay operations for proper function. Documented system conditions with photos of thermostat operation and control board assembly to verify system status and troubleshoot recurring temperature control concerns.
Responded to callback for recurring cooling issue following previous service visit. Upon arrival, verified thermostat displaying 73°F with customer reporting inadequate cooling and indoor temperature of 76°F. Inspected HVAC control board and wiring connections within air handler, checking all low-voltage control wiring, power connections, and relay operations for proper function. Documented system conditions with photos of thermostat operation and control board assembly to verify system status and troubleshoot recurring temperature control concerns.
David R.
David R. Checked in
Responded to callback for recurring cooling issue following previous service visit. Upon arrival, verified thermostat displaying 73°F with customer reporting inadequate cooling and indoor temperature of 76°F. Inspected HVAC control board and wiring connections within air handler, checking all low-voltage control wiring, power connections, and relay operations for proper function. Documented system conditions with photos of thermostat operation and control board assembly to verify system status and troubleshoot recurring temperature control concerns.
Chicago, IL 60656
Responded to warranty callback for second floor cooling issue. Performed diagnostic temperature measurements at air handler unit, recording supply air temperature of 46.3°F and return air temperature of 73.9°F, confirming system is producing adequate temperature differential and operating within normal parameters.
Responded to warranty callback for second floor cooling issue. Performed diagnostic temperature measurements at air handler unit, recording supply air temperature of 46.3°F and return air temperature of 73.9°F, confirming system is producing adequate temperature differential and operating within normal parameters.
Travis S.
Travis S. Checked in
Responded to warranty callback for second floor cooling issue. Performed diagnostic temperature measurements at air handler unit, recording supply air temperature of 46.3°F and return air temperature of 73.9°F, confirming system is producing adequate temperature differential and operating within normal parameters.
Chicago, IL 60614
Performed diagnostic evaluation on aging residential air conditioning system approximately 40 years old. Conducted visual inspection of outdoor condenser unit mounted on exterior building wall and assessed interior components. Due to advanced age of equipment, provided comprehensive repair estimate to homeowner for necessary service work.
Performed diagnostic evaluation on aging residential air conditioning system approximately 40 years old. Conducted visual inspection of outdoor condenser unit mounted on exterior building wall and assessed interior components. Due to advanced age of equipment, provided comprehensive repair estimate to homeowner for necessary service work.
Jose E.
Jose E. Checked in
Performed diagnostic evaluation on aging residential air conditioning system approximately 40 years old. Conducted visual inspection of outdoor condenser unit mounted on exterior building wall and assessed interior components. Due to advanced age of equipment, provided comprehensive repair estimate to homeowner for necessary service work.
Chicago, IL 60630
Start Saving Today With

Membership Perks

Lorem Ipsum Gen Dolor

Ipsum Gen

Start Saving Today With

Membership Perks

What To Expect

Discover the Home Comfort Difference

Premium Customer Conveniences

Home Comfort makes it easy to get service fast. With web bookings, instant estimates, filter store, and chat to text we support our customers with convenience and ease!

Available for You Every Day!

Our technicians work 7 days a week for maintenance visits and service calls, with no additional upcharges or surcharges! That means more opportunities to schedule with us, and savings for weekend visits.

Financing Available

Home Comfort offers customers a variety of financing packages to make your heating or cooling service affordable.

Commitment to Integrity & Professionalism

Our team is committed to providing honesty and expertise to our customers with every service.

Decades of Industry Expertise

The Home Comfort heating and cooling technicians bring several years of industry experience and knowledge.

Dedicated To Our Community

Home Comfort is devoted to Northwest Chicagoland residents & businesses, ensuring everyone stays comfortable.

Premium Customer Conveniences

Home Comfort makes it easy to get service fast. With web bookings, instant estimates, filter store, and chat to text we support our customers with convenience and ease!

Available for You Every Day!

Our technicians work 7 days a week for maintenance visits and service calls, with no additional upcharges or surcharges! That means more opportunities to schedule with us, and savings for weekend visits.

Financing Available

Home Comfort offers customers a variety of financing packages to make your heating or cooling service affordable.

Commitment to Integrity & Professionalism

Our team is committed to providing honesty and expertise to our customers with every service.

Decades of Industry Expertise

The Home Comfort heating and cooling technicians bring several years of industry experience and knowledge.

Dedicated To Our Community

Home Comfort is devoted to Northwest Chicagoland residents & businesses, ensuring everyone stays comfortable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

It was my pleasure having Travis work at my home. He was on time and polite, and cleaned up before he left. With over a decade of experience with Home Comfort, he knew exactly what needed to be done and was able to do it quickly…

JEC

JEC

MICHAEL and MOSES were two gentlemen servicing my air-conditioning. I appreciate their ability to come after their normal scheduled hours, due to my long working hours and going out of their way. the explanation and the way all was done was absolutely wonderful. I felt like…

Elizabeth Markiewicz

Elizabeth Markiewicz

Very detailed diagnostics and excellent communication.

Dan Rich

Dan Rich

Excellent service. Highly professional.

Jacqueline Bolda

Jacqueline Bolda

We’ve been using their services for past 25 years. Recently Jose and Ivica were at our house. We replaced the Space Pak system on our 100 year old home. We have been happy.

Maurine Conti

Maurine Conti