24/7 Heating, & AC Services in Chicago, IL | Local HVAC
24/7 Emergency Service
Contact the professionals at Home Comfort to take care of your HVAC emergency, no matter the time of day or day of the week. Did you know that any one of our super friendly technicians is on call 24/7? You're not the first customer to experience the unfortunate circumstance of no heat or no A/C at an inopportune time. We’re here for you. Call 847-824-4336 to get emergency HVAC services in Northwest Chicagoland & the surrounding areas.

Heating & Cooling Services in Chicago, IL

Maintaining consistent comfort in your Chicago-area home means having a reliable HVAC technician you can trust to service all your heating and cooling equipment. Home Comfort Services has proudly delivered the comprehensive HVAC solutions that Chicago residents have trusted since 1998.

With seven-day-a-week HVAC repair availability and a team of background-checked technicians, we go above and beyond to make your home more comfortable through our powerful service solutions.

Schedule heating or air conditioning services in Chicago today by calling our team at 847-824-4336!

Home Comfort technician at the door of a Chicago homeowner

Dependable Cooling Services

While summers in Chicago are mild, with average highs of 80 degrees F, high humidity levels over 75% can make the summer season downright intolerable without a properly functioning air conditioner. Whether you have a heat pump, ductless mini-split, or central AC unit, our cooling experts are prepared to handle all of your service requests, including:

Service and Maintenance 7 Days a Week (224) 757-1647

Top-Rated Heating Services

With winter lows averaging 25 degrees F and an annual snowfall of 37 inches, Chicago homeowners need a source of reliable heat to survive the coldest days of the year. Our team can service any make or model heating equipment, including gas and electric furnaces and boiler systems. We are here to assist whenever you need:

Keep your home warm and cozy all winter by calling Home Comfort Services at 847-824-4336 to book your heating service appointment in Chicago today!

Superior Air Quality Services

Did you know that the Environmental Protection Agency ranked poor indoor air quality as one of the top concerns for homeowners? It’s true — the air inside your home can be up to 5 times more polluted than the air outside, leading to serious health issues for your household and reduced efficiency for your HVAC equipment.

At Home Comfort Services, our team offers various indoor air quality solutions to eliminate harmful contaminants from your air supply. We specialize in:

  • Ductwork repairs & replacements
  • Air purifier installation
  • Air scrubber installation
  • Humidifier services
  • Dehumidifier services

Breathe easy in your Chicago-area home by calling 847-824-4336 to book indoor air quality services with our team today!

Why Choose Home Comfort in Chicago?

As Northwest Chicagoland’s heating and air conditioning experts since 1998, Home Comfort Services is proud to deliver a comprehensive range of HVAC solutions that local families can trust to keep their homes safe and comfortable all year. With seven-day-a-week repair availability, we are here to act when you need us most, restoring reliable comfort to your home in no time.

We are committed to integrity and professionalism in everything we do, providing honesty and expertise to our customers with every service we provide. As Premium Customer Conveniences, we remain passionate about bringing the highest quality products and solutions to your home.

Get the high-quality HVAC service experience you deserve by calling 847-824-4336 to book your heating and cooling services with Home Comfort today!

Recent Jobs and Reviews in Chicago, IL

Job Locations and Reviews

Responded to complaint of AC unit short cycling and inadequate cooling. Upon arrival, inspected York residential split system with rooftop condenser unit. Diagnosed faulty contactor causing intermittent operation and preventing compressor from maintaining steady run cycle. Replaced defective contactor, verified proper voltage and amperage draw, and tested system through complete cooling cycle. Unit now operating within manufacturer specifications with normal run times and proper temperature differential across evaporator coil.
Responded to complaint of AC unit short cycling and inadequate cooling. Upon arrival, inspected York residential split system with rooftop condenser unit. Diagnosed faulty contactor causing intermittent operation and preventing compressor from maintaining steady run cycle. Replaced defective contactor, verified proper voltage and amperage draw, and tested system through complete cooling cycle. Unit now operating within manufacturer specifications with normal run times and proper temperature differential across evaporator coil.
Michael O.
Michael O. Checked in
Responded to complaint of AC unit short cycling and inadequate cooling. Upon arrival, inspected York residential split system with rooftop condenser unit. Diagnosed faulty contactor causing intermittent operation and preventing compressor from maintaining steady run cycle. Replaced defective contactor, verified proper voltage and amperage draw, and tested system through complete cooling cycle. Unit now operating within manufacturer specifications with normal run times and proper temperature differential across evaporator coil.
Chicago, IL 60607
Replaced failed 2-stage gas valve on Luxaire furnace. Disconnected electrical connections and gas supply lines, removed old valve assembly showing signs of corrosion, and installed new gas valve unit. Reconnected all wiring to proper terminals, restored gas supply connections, and verified proper operation of ignition sequence and flame control.
Replaced failed 2-stage gas valve on Luxaire furnace. Disconnected electrical connections and gas supply lines, removed old valve assembly showing signs of corrosion, and installed new gas valve unit. Reconnected all wiring to proper terminals, restored gas supply connections, and verified proper operation of ignition sequence and flame control.
Jose E.
Jose E. Checked in
Replaced failed 2-stage gas valve on Luxaire furnace. Disconnected electrical connections and gas supply lines, removed old valve assembly showing signs of corrosion, and installed new gas valve unit. Reconnected all wiring to proper terminals, restored gas supply connections, and verified proper operation of ignition sequence and flame control.
Chicago, IL 60640
Responded to no cooling complaint on residential air conditioning system. Upon arrival, performed diagnostic testing on outdoor condensing unit. Visual inspection revealed aged equipment with significant debris accumulation on condenser coil surfaces affecting heat transfer efficiency. Conducted electrical diagnostics with multimeter on capacitor and associated components. Testing identified failed dual run capacitor preventing proper compressor and condenser fan motor operation. Removed defective capacitor and installed replacement unit with correct microfarad ratings. Verified proper electrical connections and terminal integrity. Cycled system through complete startup sequence and confirmed compressor engagement and condenser fan motor operation. Monitored amperage draw on both circuits to ensure operation within manufacturer specifications. System cooling properly and maintaining temperature setpoint at time of departure.
Responded to no cooling complaint on residential air conditioning system. Upon arrival, performed diagnostic testing on outdoor condensing unit. Visual inspection revealed aged equipment with significant debris accumulation on condenser coil surfaces affecting heat transfer efficiency. Conducted electrical diagnostics with multimeter on capacitor and associated components. Testing identified failed dual run capacitor preventing proper compressor and condenser fan motor operation. Removed defective capacitor and installed replacement unit with correct microfarad ratings. Verified proper electrical connections and terminal integrity. Cycled system through complete startup sequence and confirmed compressor engagement and condenser fan motor operation. Monitored amperage draw on both circuits to ensure operation within manufacturer specifications. System cooling properly and maintaining temperature setpoint at time of departure.
Jose E.
Jose E. Checked in
Responded to no cooling complaint on residential air conditioning system. Upon arrival, performed diagnostic testing on outdoor condensing unit. Visual inspection revealed aged equipment with significant debris accumulation on condenser coil surfaces affecting heat transfer efficiency. Conducted electrical diagnostics with multimeter on capacitor and associated components. Testing identified failed dual run capacitor preventing proper compressor and condenser fan motor operation. Removed defective capacitor and installed replacement unit with correct microfarad ratings. Verified proper electrical connections and terminal integrity. Cycled system through complete startup sequence and confirmed compressor engagement and condenser fan motor operation. Monitored amperage draw on both circuits to ensure operation within manufacturer specifications. System cooling properly and maintaining temperature setpoint at time of departure.
Chicago, IL 60634
Completed annual air conditioning clean and check maintenance per comfort plan agreement on Bosch system. Performed comprehensive inspection of outdoor condensing unit and indoor air handler control board, verified all electrical connections and components operating within normal parameters, documented system condition with photos showing circuit board with proper LED indicators and clean outdoor unit with intact housing and protective guards.
Completed annual air conditioning clean and check maintenance per comfort plan agreement on Bosch system. Performed comprehensive inspection of outdoor condensing unit and indoor air handler control board, verified all electrical connections and components operating within normal parameters, documented system condition with photos showing circuit board with proper LED indicators and clean outdoor unit with intact housing and protective guards.
Jose E.
Jose E. Checked in
Completed annual air conditioning clean and check maintenance per comfort plan agreement on Bosch system. Performed comprehensive inspection of outdoor condensing unit and indoor air handler control board, verified all electrical connections and components operating within normal parameters, documented system condition with photos showing circuit board with proper LED indicators and clean outdoor unit with intact housing and protective guards.
Chicago, IL 60660
Completed Silver Comfort Plan clean and check on one air conditioning system. Performed standard maintenance inspection with electrical diagnostics using clamp meter to verify proper amperage draw on compressor and blower motor, confirming system operation within manufacturer specifications. Customer declined water heater and humidifier service at this time.
Completed Silver Comfort Plan clean and check on one air conditioning system. Performed standard maintenance inspection with electrical diagnostics using clamp meter to verify proper amperage draw on compressor and blower motor, confirming system operation within manufacturer specifications. Customer declined water heater and humidifier service at this time.
Jose E.
Jose E. Checked in
Completed Silver Comfort Plan clean and check on one air conditioning system. Performed standard maintenance inspection with electrical diagnostics using clamp meter to verify proper amperage draw on compressor and blower motor, confirming system operation within manufacturer specifications. Customer declined water heater and humidifier service at this time.
Chicago, IL 60656
Completed full system replacement including reclamation of existing refrigerant from old condenser, coil, and line-set, followed by disconnection and proper disposal of all existing equipment. Installed new Lennox 3-ton 13 SEER2 single-stage air conditioning condensing unit (Model ML13KC1-036-230) on new pad with pea gravel leveling, along with matching evaporator coil connected to existing copper refrigerant lines. Performed complete system evacuation to remove moisture and air, then charged with R410a refrigerant to manufacturer specifications. Installed RDS mitigation system as required. Conducted comprehensive start-up procedures, system testing, and safety inspection with all operating parameters verified within normal range, including pressure readings of 246.5 PSig low-side and 247.6 PSig high-side at 4.0°F.
Completed full system replacement including reclamation of existing refrigerant from old condenser, coil, and line-set, followed by disconnection and proper disposal of all existing equipment. Installed new Lennox 3-ton 13 SEER2 single-stage air conditioning condensing unit (Model ML13KC1-036-230) on new pad with pea gravel leveling, along with matching evaporator coil connected to existing copper refrigerant lines. Performed complete system evacuation to remove moisture and air, then charged with R410a refrigerant to manufacturer specifications. Installed RDS mitigation system as required. Conducted comprehensive start-up procedures, system testing, and safety inspection with all operating parameters verified within normal range, including pressure readings of 246.5 PSig low-side and 247.6 PSig high-side at 4.0°F.
Filo A.
Filo A. Checked in
Completed full system replacement including reclamation of existing refrigerant from old condenser, coil, and line-set, followed by disconnection and proper disposal of all existing equipment. Installed new Lennox 3-ton 13 SEER2 single-stage air conditioning condensing unit (Model ML13KC1-036-230) on new pad with pea gravel leveling, along with matching evaporator coil connected to existing copper refrigerant lines. Performed complete system evacuation to remove moisture and air, then charged with R410a refrigerant to manufacturer specifications. Installed RDS mitigation system as required. Conducted comprehensive start-up procedures, system testing, and safety inspection with all operating parameters verified within normal range, including pressure readings of 246.5 PSig low-side and 247.6 PSig high-side at 4.0°F.
Chicago, IL 60630
Responded to warranty call for HVAC system installed in 2022. Located and identified leaking valve connected to furnace, performed necessary repairs to resolve water leak issue. Documented equipment condition and completed repair work to restore system to proper operating condition.
Responded to warranty call for HVAC system installed in 2022. Located and identified leaking valve connected to furnace, performed necessary repairs to resolve water leak issue. Documented equipment condition and completed repair work to restore system to proper operating condition.
David R.
David R. Checked in
Responded to warranty call for HVAC system installed in 2022. Located and identified leaking valve connected to furnace, performed necessary repairs to resolve water leak issue. Documented equipment condition and completed repair work to restore system to proper operating condition.
Chicago, IL 60647
Completed Comfort Plan clean and check maintenance on 14-year-old residential air conditioning system. Performed comprehensive inspection of indoor furnace unit and outdoor condensing unit, including visual assessment of electrical connections, refrigerant lines, and ductwork. Measured electrical parameters using clamp meter to verify proper system operation and component performance within manufacturer specifications.
Completed Comfort Plan clean and check maintenance on 14-year-old residential air conditioning system. Performed comprehensive inspection of indoor furnace unit and outdoor condensing unit, including visual assessment of electrical connections, refrigerant lines, and ductwork. Measured electrical parameters using clamp meter to verify proper system operation and component performance within manufacturer specifications.
David R.
David R. Checked in
Completed Comfort Plan clean and check maintenance on 14-year-old residential air conditioning system. Performed comprehensive inspection of indoor furnace unit and outdoor condensing unit, including visual assessment of electrical connections, refrigerant lines, and ductwork. Measured electrical parameters using clamp meter to verify proper system operation and component performance within manufacturer specifications.
Chicago, IL 60626
Completed comprehensive tune-up service on single AC/AH system. Inspected blower wheel assembly and verified proper operation, noting minor dust accumulation on squirrel cage fan blades. Performed electrical diagnostics using clamp meter to verify system amperage and proper voltage delivery to outdoor condensing unit. Inspected condenser coil condition, electrical connections, and wiring integrity at outdoor unit. All components operating within normal parameters upon completion of maintenance service.
Completed comprehensive tune-up service on single AC/AH system. Inspected blower wheel assembly and verified proper operation, noting minor dust accumulation on squirrel cage fan blades. Performed electrical diagnostics using clamp meter to verify system amperage and proper voltage delivery to outdoor condensing unit. Inspected condenser coil condition, electrical connections, and wiring integrity at outdoor unit. All components operating within normal parameters upon completion of maintenance service.
Elliot H.
Elliot H. Checked in
Completed comprehensive tune-up service on single AC/AH system. Inspected blower wheel assembly and verified proper operation, noting minor dust accumulation on squirrel cage fan blades. Performed electrical diagnostics using clamp meter to verify system amperage and proper voltage delivery to outdoor condensing unit. Inspected condenser coil condition, electrical connections, and wiring integrity at outdoor unit. All components operating within normal parameters upon completion of maintenance service.
Chicago, IL 60656
Completed comprehensive Comfort Plan maintenance service on two HVAC systems. Performed clean and check procedures on both units, including inspection of blower motor assembly, gas valve components, electrical connections, and all associated wiring. Verified proper operation of furnace components, examined air filter dimensions (16x25x1), and documented temperature readings at 67.2°F. All systems found operating within normal parameters with no immediate service concerns identified.
Completed comprehensive Comfort Plan maintenance service on two HVAC systems. Performed clean and check procedures on both units, including inspection of blower motor assembly, gas valve components, electrical connections, and all associated wiring. Verified proper operation of furnace components, examined air filter dimensions (16x25x1), and documented temperature readings at 67.2°F. All systems found operating within normal parameters with no immediate service concerns identified.
Jacob R.
Jacob R. Checked in
Completed comprehensive Comfort Plan maintenance service on two HVAC systems. Performed clean and check procedures on both units, including inspection of blower motor assembly, gas valve components, electrical connections, and all associated wiring. Verified proper operation of furnace components, examined air filter dimensions (16x25x1), and documented temperature readings at 67.2°F. All systems found operating within normal parameters with no immediate service concerns identified.
Chicago, IL 60631
Completed preventive maintenance tune-up on single-system rooftop EcoGuide air conditioning unit. Performed comprehensive electrical diagnostics using clamp meter, measuring amperage draws and verifying proper electrical operation of compressor and fan motor circuits. Inspected capacitor condition, refrigerant line connections, and overall system components. Unit operating within normal parameters; customer provided own filter for replacement. System checked and cleared for continued operation.
Completed preventive maintenance tune-up on single-system rooftop EcoGuide air conditioning unit. Performed comprehensive electrical diagnostics using clamp meter, measuring amperage draws and verifying proper electrical operation of compressor and fan motor circuits. Inspected capacitor condition, refrigerant line connections, and overall system components. Unit operating within normal parameters; customer provided own filter for replacement. System checked and cleared for continued operation.
Elliot H.
Elliot H. Checked in
Completed preventive maintenance tune-up on single-system rooftop EcoGuide air conditioning unit. Performed comprehensive electrical diagnostics using clamp meter, measuring amperage draws and verifying proper electrical operation of compressor and fan motor circuits. Inspected capacitor condition, refrigerant line connections, and overall system components. Unit operating within normal parameters; customer provided own filter for replacement. System checked and cleared for continued operation.
Chicago, IL 60656
Responded to no-cool complaint on 15+ year old split system. Upon arrival, confirmed indoor blower operational and heating mode functional, but outdoor condensing unit failed to energize when thermostat called for cooling. Performed visual inspection of outdoor unit and found severely weathered equipment with significant corrosion on cabinet and mounting bracket. Removed electrical access panel and diagnosed failed dual-run capacitor with visible bulging and discoloration. Tested contactor operation and verified proper thermostat signal at low-voltage terminals. Replaced defective capacitor with appropriate microfarad-rated component, secured all electrical connections, and restored power to system. Cycled unit through complete cooling operation and confirmed compressor and condenser fan motor startup with normal amperage draw. System now cooling properly with adequate airflow and refrigerant pressures within manufacturer specifications.
Responded to no-cool complaint on 15+ year old split system. Upon arrival, confirmed indoor blower operational and heating mode functional, but outdoor condensing unit failed to energize when thermostat called for cooling. Performed visual inspection of outdoor unit and found severely weathered equipment with significant corrosion on cabinet and mounting bracket. Removed electrical access panel and diagnosed failed dual-run capacitor with visible bulging and discoloration. Tested contactor operation and verified proper thermostat signal at low-voltage terminals. Replaced defective capacitor with appropriate microfarad-rated component, secured all electrical connections, and restored power to system. Cycled unit through complete cooling operation and confirmed compressor and condenser fan motor startup with normal amperage draw. System now cooling properly with adequate airflow and refrigerant pressures within manufacturer specifications.
Travis S.
Travis S. Checked in
Responded to no-cool complaint on 15+ year old split system. Upon arrival, confirmed indoor blower operational and heating mode functional, but outdoor condensing unit failed to energize when thermostat called for cooling. Performed visual inspection of outdoor unit and found severely weathered equipment with significant corrosion on cabinet and mounting bracket. Removed electrical access panel and diagnosed failed dual-run capacitor with visible bulging and discoloration. Tested contactor operation and verified proper thermostat signal at low-voltage terminals. Replaced defective capacitor with appropriate microfarad-rated component, secured all electrical connections, and restored power to system. Cycled unit through complete cooling operation and confirmed compressor and condenser fan motor startup with normal amperage draw. System now cooling properly with adequate airflow and refrigerant pressures within manufacturer specifications.
Chicago, IL 60634
Completed comprehensive clean and check service on air conditioning system and air handler unit. Performed thorough inspection of internal components including blower assembly, evaporator coil, electrical connections, and wiring harnesses. Tested capacitor functionality and verified electrical readings using digital clamp meter, confirming all values within normal operating parameters. All mechanical and electrical components found operating properly with no deficiencies noted.
Completed comprehensive clean and check service on air conditioning system and air handler unit. Performed thorough inspection of internal components including blower assembly, evaporator coil, electrical connections, and wiring harnesses. Tested capacitor functionality and verified electrical readings using digital clamp meter, confirming all values within normal operating parameters. All mechanical and electrical components found operating properly with no deficiencies noted.
Elliot H.
Elliot H. Checked in
Completed comprehensive clean and check service on air conditioning system and air handler unit. Performed thorough inspection of internal components including blower assembly, evaporator coil, electrical connections, and wiring harnesses. Tested capacitor functionality and verified electrical readings using digital clamp meter, confirming all values within normal operating parameters. All mechanical and electrical components found operating properly with no deficiencies noted.
Chicago, IL 60656
Completed comprehensive tune-up on rooftop air conditioning system for new customer. Performed standard maintenance procedures including system diagnostics with multimeter, electrical component inspection of capacitor and contactor assembly, and installed new 12x20x1 air filter. All components tested within normal operating parameters and system returned to service.
Completed comprehensive tune-up on rooftop air conditioning system for new customer. Performed standard maintenance procedures including system diagnostics with multimeter, electrical component inspection of capacitor and contactor assembly, and installed new 12x20x1 air filter. All components tested within normal operating parameters and system returned to service.
Elliot H.
Elliot H. Checked in
Completed comprehensive tune-up on rooftop air conditioning system for new customer. Performed standard maintenance procedures including system diagnostics with multimeter, electrical component inspection of capacitor and contactor assembly, and installed new 12x20x1 air filter. All components tested within normal operating parameters and system returned to service.
Chicago, IL 60656
Completed comprehensive tune-up service on HVAC system with air handler and condenser unit. Inspected and replaced heavily soiled air filter with custom-sized 14-1/2x17-1/2x1/2 filter as requested, which showed significant dust accumulation and uneven particulate loading across the filter media. Performed standard maintenance procedures including system performance evaluation, component inspection, and verification of proper airflow through return air filtration system.
Completed comprehensive tune-up service on HVAC system with air handler and condenser unit. Inspected and replaced heavily soiled air filter with custom-sized 14-1/2x17-1/2x1/2 filter as requested, which showed significant dust accumulation and uneven particulate loading across the filter media. Performed standard maintenance procedures including system performance evaluation, component inspection, and verification of proper airflow through return air filtration system.
Craig S.
Craig S. Checked in
Completed comprehensive tune-up service on HVAC system with air handler and condenser unit. Inspected and replaced heavily soiled air filter with custom-sized 14-1/2x17-1/2x1/2 filter as requested, which showed significant dust accumulation and uneven particulate loading across the filter media. Performed standard maintenance procedures including system performance evaluation, component inspection, and verification of proper airflow through return air filtration system.
Chicago, IL 60656
Performed comprehensive tune-up and diagnostic evaluation on rooftop HVAC system serving single zone. Conducted electrical testing using digital multimeter, verifying capacitor operation and measuring voltage readings at evaporator coil assembly. Noted significant deterioration and corrosion on condenser coil with heavy oxidation throughout finned surfaces, which will impact system efficiency and heat transfer capability. Collected service fee and documented equipment condition with photographic evidence for customer records.
Performed comprehensive tune-up and diagnostic evaluation on rooftop HVAC system serving single zone. Conducted electrical testing using digital multimeter, verifying capacitor operation and measuring voltage readings at evaporator coil assembly. Noted significant deterioration and corrosion on condenser coil with heavy oxidation throughout finned surfaces, which will impact system efficiency and heat transfer capability. Collected service fee and documented equipment condition with photographic evidence for customer records.
Elliot H.
Elliot H. Checked in
Performed comprehensive tune-up and diagnostic evaluation on rooftop HVAC system serving single zone. Conducted electrical testing using digital multimeter, verifying capacitor operation and measuring voltage readings at evaporator coil assembly. Noted significant deterioration and corrosion on condenser coil with heavy oxidation throughout finned surfaces, which will impact system efficiency and heat transfer capability. Collected service fee and documented equipment condition with photographic evidence for customer records.
Chicago, IL 60656
Completed comprehensive tune-up service on rooftop commercial HVAC system including air conditioning condenser unit and air handler. Performed standard maintenance protocol: inspected all mechanical components, checked refrigerant lines and connections, verified proper operation of condenser fan and motor, examined electrical connections and controls, tested system performance parameters, and replaced air filter. All equipment found operating within normal specifications with no deficiencies noted at time of service.
Completed comprehensive tune-up service on rooftop commercial HVAC system including air conditioning condenser unit and air handler. Performed standard maintenance protocol: inspected all mechanical components, checked refrigerant lines and connections, verified proper operation of condenser fan and motor, examined electrical connections and controls, tested system performance parameters, and replaced air filter. All equipment found operating within normal specifications with no deficiencies noted at time of service.
Jacob R.
Jacob R. Checked in
Completed comprehensive tune-up service on rooftop commercial HVAC system including air conditioning condenser unit and air handler. Performed standard maintenance protocol: inspected all mechanical components, checked refrigerant lines and connections, verified proper operation of condenser fan and motor, examined electrical connections and controls, tested system performance parameters, and replaced air filter. All equipment found operating within normal specifications with no deficiencies noted at time of service.
Chicago, IL 60656
Completed comprehensive tune-up maintenance on single-system HVAC unit, including outdoor condensing unit and indoor air handler. Performed standard cleaning and inspection protocols, with customer declining filter replacement at time of service.
Completed comprehensive tune-up maintenance on single-system HVAC unit, including outdoor condensing unit and indoor air handler. Performed standard cleaning and inspection protocols, with customer declining filter replacement at time of service.
Craig S.
Craig S. Checked in
Completed comprehensive tune-up maintenance on single-system HVAC unit, including outdoor condensing unit and indoor air handler. Performed standard cleaning and inspection protocols, with customer declining filter replacement at time of service.
Chicago, IL 60656
Conducted comprehensive assessment of existing HVAC and hydronic heating system for planned residential renovation project. Evaluated current basement mechanical room containing water heater, expansion tank, and complex piping network including copper, black insulated, and color-coded distribution lines with multiple valves and gauges. Documented existing two-tone painted mechanical space with overhead piping infrastructure and window access. Reviewed architectural plans specifying retention of select radiators while replacing others with baseboard units. Assessed feasibility of installing new combination hot water/boiler system in basement to serve primary heating zones. Evaluated existing R410A outdoor compressor unit for compatibility and potential reuse with planned Space-Pak high-velocity air conditioning system to be installed in attic location near current equipment. Confirmed separate inline water heater specification for two new attic bathroom additions independent of main hea
Conducted comprehensive assessment of existing HVAC and hydronic heating system for planned residential renovation project. Evaluated current basement mechanical room containing water heater, expansion tank, and complex piping network including copper, black insulated, and color-coded distribution lines with multiple valves and gauges. Documented existing two-tone painted mechanical space with overhead piping infrastructure and window access. Reviewed architectural plans specifying retention of select radiators while replacing others with baseboard units. Assessed feasibility of installing new combination hot water/boiler system in basement to serve primary heating zones. Evaluated existing R410A outdoor compressor unit for compatibility and potential reuse with planned Space-Pak high-velocity air conditioning system to be installed in attic location near current equipment. Confirmed separate inline water heater specification for two new attic bathroom additions independent of main hea
Dustin M.
Dustin M. Checked in
Conducted comprehensive assessment of existing HVAC and hydronic heating system for planned residential renovation project. Evaluated current basement mechanical room containing water heater, expansion tank, and complex piping network including copper, black insulated, and color-coded distribution lines with multiple valves and gauges. Documented existing two-tone painted mechanical space with overhead piping infrastructure and window access. Reviewed architectural plans specifying retention of select radiators while replacing others with baseboard units. Assessed feasibility of installing new combination hot water/boiler system in basement to serve primary heating zones. Evaluated existing R410A outdoor compressor unit for compatibility and potential reuse with planned Space-Pak high-velocity air conditioning system to be installed in attic location near current equipment. Confirmed separate inline water heater specification for two new attic bathroom additions independent of main hea
Chicago, IL 60613
Completed comprehensive plumbing and HVAC system integration work at residential property. Piped 1/2" recirculation line into tankless water heater and connected to main recirculation line, replacing unistrut clamps with cushion clamps for proper support. Removed two temporary 1/2" ball valves previously installed for shower, capped cold line, and installed 1/4" compression x 1/2" compression angle stop on hot line for humidifier connection. Reworked condensate drain system for AC coil and humidifier to ensure proper drainage. Rerouted ERV flex lines to run over main hot and cold water lines, eliminating interference issues. Connected ERV 2-wire control wiring from energy recovery ventilator unit and ran to interface module location. Completed electrical wiring of interface module to control ERV and humidifier operation. Programmed thermostat to communicate with interface module for integrated system control. Programmed tankless water heater settings to properly operate recirculation p
Completed comprehensive plumbing and HVAC system integration work at residential property. Piped 1/2" recirculation line into tankless water heater and connected to main recirculation line, replacing unistrut clamps with cushion clamps for proper support. Removed two temporary 1/2" ball valves previously installed for shower, capped cold line, and installed 1/4" compression x 1/2" compression angle stop on hot line for humidifier connection. Reworked condensate drain system for AC coil and humidifier to ensure proper drainage. Rerouted ERV flex lines to run over main hot and cold water lines, eliminating interference issues. Connected ERV 2-wire control wiring from energy recovery ventilator unit and ran to interface module location. Completed electrical wiring of interface module to control ERV and humidifier operation. Programmed thermostat to communicate with interface module for integrated system control. Programmed tankless water heater settings to properly operate recirculation p
Travis S.
Travis S. Checked in
Completed comprehensive plumbing and HVAC system integration work at residential property. Piped 1/2" recirculation line into tankless water heater and connected to main recirculation line, replacing unistrut clamps with cushion clamps for proper support. Removed two temporary 1/2" ball valves previously installed for shower, capped cold line, and installed 1/4" compression x 1/2" compression angle stop on hot line for humidifier connection. Reworked condensate drain system for AC coil and humidifier to ensure proper drainage. Rerouted ERV flex lines to run over main hot and cold water lines, eliminating interference issues. Connected ERV 2-wire control wiring from energy recovery ventilator unit and ran to interface module location. Completed electrical wiring of interface module to control ERV and humidifier operation. Programmed thermostat to communicate with interface module for integrated system control. Programmed tankless water heater settings to properly operate recirculation p
Chicago, IL 60657
Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover the Home Comfort Difference

Premium Customer Conveniences

Home Comfort makes it easy to get service fast. With web bookings, instant estimates, filter store, and chat to text we support our customers with convenience and ease!

Available for You Every Day!

Our technicians work 7 days a week for maintenance visits and service calls, with no additional upcharges or surcharges! That means more opportunities to schedule with us, and savings for weekend visits.

Financing Available

Home Comfort offers customers a variety of financing packages to make your heating or cooling service affordable.

Commitment to Integrity & Professionalism

Our team is committed to providing honesty and expertise to our customers with every service.

Decades of Industry Expertise

The Home Comfort heating and cooling technicians bring several years of industry experience and knowledge.

Dedicated To Our Community

Home Comfort is devoted to Northwest Chicagoland residents & businesses, ensuring everyone stays comfortable.

Premium Customer Conveniences

Home Comfort makes it easy to get service fast. With web bookings, instant estimates, filter store, and chat to text we support our customers with convenience and ease!

Available for You Every Day!

Our technicians work 7 days a week for maintenance visits and service calls, with no additional upcharges or surcharges! That means more opportunities to schedule with us, and savings for weekend visits.

Financing Available

Home Comfort offers customers a variety of financing packages to make your heating or cooling service affordable.

Commitment to Integrity & Professionalism

Our team is committed to providing honesty and expertise to our customers with every service.

Decades of Industry Expertise

The Home Comfort heating and cooling technicians bring several years of industry experience and knowledge.

Dedicated To Our Community

Home Comfort is devoted to Northwest Chicagoland residents & businesses, ensuring everyone stays comfortable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

It was my pleasure having Travis work at my home. He was on time and polite, and cleaned up before he left. With over a decade of experience with Home Comfort, he knew exactly what needed to be done and was able to do it quickly…

JEC

JEC

MICHAEL and MOSES were two gentlemen servicing my air-conditioning. I appreciate their ability to come after their normal scheduled hours, due to my long working hours and going out of their way. the explanation and the way all was done was absolutely wonderful. I felt like…

Elizabeth Markiewicz

Elizabeth Markiewicz

Very detailed diagnostics and excellent communication.

Dan Rich

Dan Rich

Excellent service. Highly professional.

Jacqueline Bolda

Jacqueline Bolda

We’ve been using their services for past 25 years. Recently Jose and Ivica were at our house. We replaced the Space Pak system on our 100 year old home. We have been happy.

Maurine Conti

Maurine Conti